Carlin Oil Burners
|
|
ResidentialCarlin EZ Pro Advanced Oil Burner0.5 to 2.06 GPH Available with or without a burner cover. The EZ-Pro advanced oil burner combines the proven range and reliability of the EZ burner with Carlin's line of electronic controls and high efficiency components. Purchase the EZ-Pro in any of three configurations - EZ-1, EZ-2, or EZ-3. Specify tube length when ordering. |
|
Input
|
EZ-1: 0.5 to 1.65 GPH EZ-2: 1.50 to 2.25 GPH EZ-3: 2.00 to 2.50 GPH |
|
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil Canada - No. 1 Oil or No. 2 Furnace Oil |
|
|
Electrical
|
Power: 120 vac, 60Hz, 1-Phase Current: Approximately 5.8 Amps Limit Circuit Input: 120 vac, 60 Hz Motor (PSC): 1/6 HP, 3450 RPM Motor Frame: 48-Frame, "M" Flange Oil Valve Power: 120 vac, 60 Hz Nozzle Line Heater: 120 vac, 60 Hz Alarm Contacts (Isolated): 24 VAC/VDC, 2 Amps |
|
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
|
Control
|
Carlin Model 60200 Microprocessor Control 15 sec. Trial for Ignition (TFI) 1.3 sec. FFRT Pre-purge and post-purge (10 seconds) Serviceman reset protection (Latch-up after three consecutive lockouts) Interrupted Duty Ignition Recycle on flame failure |
|
|
Operating Temperature Limits
|
Maximum Ambient: 104° F (40° C) | |
|
Agencies
|
UL Listed: US & Canada |
|
|
CommercialModel 201 & 301 CRD Oil Burners
2.5 to 5.5 GPH & 3.0 to 7.0 GPH 201CRD and 301CRD advanced oil burners feature Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. Proven for years in the field and in extensive boiler and furnace testing, these burners will meet your needs for commercial oil-burning applications.6. |
|
Input
|
201CRD: 2.50 to 5.50 GPH | |
| 301CRD (3 1/4" Air Cone, "B" Style): 3.00 to 6.00 GPH | ||
| 301CRD (3 1/2" Air Cone, "C" Style): 4.00 to 7.00 GPH | ||
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil | |
| Canada - No. 1 Oil or No. 2 Furnace Oil | ||
|
Nozzle |
(1) Required, Sized for 150 PSIG | |
|
Fuel Unit
|
1-Stage, 100-15- PSIG, 7 GPH | |
|
Oil Valve
|
Instant Open Carlin SVC1OFF | |
|
Control
|
Carlin 60200 Primary Control | |
|
Electrical
|
Power: 120 vac/60Hz/1-Phase | |
| Current: Approx. 3.3 amps | ||
| Limit Circuit Input (60200 Primary): 120 vac/60 Hz | ||
| Motor (PSC): 1/4 HP, 3450 RPM, 60 Hz | ||
| Motor Frame: 48-Frame, "N" Flange | ||
| Optional Oil Valve Power: 120 vac/60 Hz | ||
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
| Ignition Voltage: 14,000 volts | ||
|
Agencies
|
UL Listed: US & Canada |
|
|
CommercialModel 601 CRD Oil Burners
6.0 to 13.2 GPH The 601CRD advanced oil burner features Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. Proven for years in the field and in extensive boiler and furnace testing, these burners will meet your needs for commercial oil-burning applications. |
|
Input
|
6.0 to 13.2 GPH | |
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil | |
| Canada - No. 1 Oil or No. 2 Furnace Oil | ||
|
Nozzles |
(1) Required, Sized 45° "SS" Hago or 45° "H" Hago | |
|
Fuel Unit
|
2-Stage, "B" Style,150 PSIG | |
|
Oil Valves
|
Instant Open Carlin SVC1OFF | |
|
Control
|
Carlin 60200 Primary Control | |
|
Electrical
|
Power: 120 vac/60Hz/1-Phase | |
| Current: Approx. 9.0 amps | ||
| Limit Circuit Input (60200 Primary): 120 vac/60 Hz | ||
| Motor: 1/2 HP, 3450 RPM, 60 Hz, Optional 208-230 vac/60 Hz | ||
| Motor Frame: 48-Frame, "N" Flange | ||
| Oil Valve Power: 120 vac/60 Hz | ||
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
| Ignition Voltage: 14,000 volts | ||
|
Agencies
|
UL Listed: US & Canada |
|
|
CommercialModel 702 CRD Oil Burners
6.0 to 13.0 GPH (High-Fire Input Capacities) The 702CRD advanced oil burner features Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 1.7:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners. |
|
Input
|
High Fire: 6.0 to 13.2 GPH | |
| Low Fire: 3.5 to 7.5 GPH | ||
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil | |
| Canada - No. 1 Oil or No. 2 Furnace Oil | ||
|
Nozzle |
(1) Required, pattern and angle vary with application | |
|
Fuel Unit
|
2-Stage, Dual Pressure 100/300 PSIG | |
|
Oil Valves
|
(2) Oil solenoid valve (safety and low fire valves) | |
| (1) Oil solenoid valve, pump mounted (high-fire valve) | ||
|
Control
|
Carlin 60200 Primary Control | |
|
Electrical
|
Power: 120 vac/60Hz/1-Phase | |
| Limit Circuit Input (60200 Primary): 120 vac/60 Hz | ||
| Control Circuit Load: 120 vac, 1.2 amps | ||
| Motor: 1/2 HP, 3450 RPM, 60 Hz, Optional 115/208-230 vac, 60 Hz, 1 phase, 8.4/3.8-4.2 amps | ||
| Motor Frame: 48-Frame, "N" Flange | ||
| Oil Valve Power: 120 vac/60 Hz | ||
| Damper Motor (With End Switch): Honeywell M436A | ||
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
| Ignition Voltage: 14,000 volts | ||
|
Agencies
|
UL Listed: US & Canada |
|
|
CommercialModel 701 & 801 CRD Oil Burners
6.0 to 13.2 GPH & 11.4 to 19.8 GPH The 701CRD and 801CRD advanced oil burners feature Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 2:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners. |
|
Input
|
701CRD: High Fire: 6.0 to 13.2 GPH, Low Fire: 3.6 to 6.6 GPH | |
| 801CRD: High Fire: 11.4 to 19.8 GPH, Low Fire: 6.6 to 8.4 GPH | ||
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil | |
| Canada - No. 1 Oil or No. 2 Furnace Oil | ||
|
Nozzles |
(1) Low Fire Nozzle, (1) High Fire Nozzle, pattern and angle vary with application | |
|
Fuel Unit
|
2-Stage, "B" Style, 150 PSIG | |
|
Oil Valves
|
(2) Oil solenoid valves | |
|
Control
|
Carlin 60200 Primary Control | |
|
Electrical
|
Power: 120 vac/60Hz/1-Phase | |
| Limit Circuit Input (60200 Primary): 120 vac/60 Hz | ||
| Control Circuit Load: 120 vac, 1.2 amps | ||
|
Motor: |
||
| Motor Frame: 701CRD: 48-Frame, "N" Flange 801CRD: 56C-Frame |
||
| Oil Valve Power: 120 vac/60 Hz | ||
| Damper Motor (With End Switch): Honeywell M436A | ||
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
| Ignition Voltage: 14,000 volts | ||
|
Agencies
|
UL Listed: US & Canada |
|
|
CommercialModel 1050 & 1150 FFD Oil Burners
15.0 to 25.0 GPH & 20.0 to 35.0 GPH The 1050FFD and 1150FFD advanced oil burners feature Carlin's flame-funnel combustion head design - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 2:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners. |
|
Input
|
1050FFD: High Fire: 15.0 to 25.0 GPH, Low Fire: 9.0 to 12.0 GPH | |
| 1150FFD: High Fire: 20.0 to 35.0 GPH, Low Fire: 12.0 to 15.0 GPH | ||
|
Fuels
|
U.S. - No. 1 or No. 2 Fuel Oil | |
| Canada - No. 1 Oil or No. 2 Furnace Oil | ||
|
Nozzles |
(3) 45° "SS" Hago | |
|
Fuel Unit
|
2-Stage, "H" Style, 100 PSIG | |
|
Oil Valves
|
(2) Oil solenoid valves | |
|
Control
|
1050FFD (To 20 GPH Only): Carlin 60200 Primary Control | |
| 1050FFD & 1150FFD (Over 20 GPH): Specify Control Set | ||
|
Electrical
|
Power: 120 vac/60Hz/1-Phase | |
| Limit Circuit Input (60200 Primary): 120 vac/60 Hz | ||
| Control Circuit Load: 120 vac, 1.2 amps | ||
|
Motor: |
||
| Motor Frame: 1050FFD: 56C Frame 1150FFD: 56C Frame |
||
| Oil Valve Power: 120 vac/60 Hz | ||
| Damper Motor (With End Switch): Honeywell M436A | ||
|
Ignition
|
Carlin Model 41000 solid state electronic ignition |
|
| Ignition Voltage: 14,000 volts | ||
|
Agencies
|
UL Listed: US & Canada |