Carlin Oil Burners

 

Carlin EZ Pro Oil Burner

 

Residential

Carlin EZ Pro Advanced Oil Burner

0.5 to 2.06 GPH

Available with or without a burner cover. The EZ-Pro advanced oil burner combines the proven range and reliability of the EZ burner with Carlin's line of electronic controls and high efficiency components. Purchase the EZ-Pro in any of three configurations - EZ-1, EZ-2, or EZ-3. Specify tube length when ordering.

Input
  EZ-1: 0.5 to 1.65 GPH
EZ-2: 1.50 to 2.25 GPH
EZ-3: 2.00 to 2.50 GPH
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil
Canada - No. 1 Oil or No. 2 Furnace Oil
Electrical
  Power: 120 vac, 60Hz, 1-Phase
Current: Approximately 5.8 Amps
Limit Circuit Input: 120 vac, 60 Hz
Motor (PSC): 1/6 HP, 3450 RPM
Motor Frame: 48-Frame, "M" Flange
Oil Valve Power: 120 vac, 60 Hz
Nozzle Line Heater: 120 vac, 60 Hz
Alarm Contacts (Isolated): 24 VAC/VDC, 2 Amps
Ignition
 

Carlin Model 41000 solid state electronic ignition
Ignition Voltage: 14,000 volts

Control
  Carlin Model 60200 Microprocessor Control
15 sec. Trial for Ignition (TFI)
1.3 sec. FFRT
Pre-purge and post-purge (10 seconds)
Serviceman reset protection (Latch-up after three consecutive lockouts)
Interrupted Duty Ignition
Recycle on flame failure
Operating Temperature Limits
  Maximum Ambient: 104° F (40° C)
Agencies
  UL Listed: US & Canada

 

Carlin 201 & 301 CRD Oil Burner

 

Commercial

Model 201 & 301 CRD Oil Burners

2.5 to 5.5 GPH & 3.0 to 7.0 GPH

201CRD and 301CRD advanced oil burners feature Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. Proven for years in the field and in extensive boiler and furnace testing, these burners will meet your needs for commercial oil-burning applications.6.

Input
  201CRD: 2.50 to 5.50 GPH

  301CRD (3 1/4" Air Cone, "B" Style): 3.00 to 6.00 GPH
    301CRD (3 1/2" Air Cone, "C" Style): 4.00 to 7.00 GPH

 
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil

  Canada - No. 1 Oil or No. 2 Furnace Oil

 

Nozzle


(1) Required, Sized for 150 PSIG



Fuel Unit

1-Stage, 100-15- PSIG, 7 GPH



Oil Valve

Instant Open Carlin SVC1OFF
     
Control
  Carlin 60200 Primary Control
     
Electrical
  Power: 120 vac/60Hz/1-Phase

  Current: Approx. 3.3 amps

  Limit Circuit Input (60200 Primary): 120 vac/60 Hz

  Motor (PSC): 1/4 HP, 3450 RPM, 60 Hz
    Motor Frame: 48-Frame, "N" Flange

  Optional Oil Valve Power: 120 vac/60 Hz

 
Ignition
 

Carlin Model 41000 solid state electronic ignition


  Ignition Voltage: 14,000 volts

 
Agencies
  UL Listed: US & Canada

 

Carlin 601 CRD Oil Burner

 

Commercial

Model 601 CRD Oil Burners

6.0 to 13.2 GPH

The 601CRD advanced oil burner features Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. Proven for years in the field and in extensive boiler and furnace testing, these burners will meet your needs for commercial oil-burning applications.

Input
  6.0 to 13.2 GPH

 
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil

  Canada - No. 1 Oil or No. 2 Furnace Oil

 

Nozzles


(1) Required, Sized 45° "SS" Hago or 45° "H" Hago



Fuel Unit

2-Stage, "B" Style,150 PSIG



Oil Valves

Instant Open Carlin SVC1OFF
     
Control
  Carlin 60200 Primary Control
     
Electrical
  Power: 120 vac/60Hz/1-Phase

  Current: Approx. 9.0 amps

  Limit Circuit Input (60200 Primary): 120 vac/60 Hz

  Motor: 1/2 HP, 3450 RPM, 60 Hz, Optional 208-230 vac/60 Hz
    Motor Frame: 48-Frame, "N" Flange

  Oil Valve Power: 120 vac/60 Hz

 
Ignition
 

Carlin Model 41000 solid state electronic ignition


  Ignition Voltage: 14,000 volts

 
Agencies
  UL Listed: US & Canada

 

Carlin 702 CRD Oil Burner

 

Commercial

Model 702 CRD Oil Burners

6.0 to 13.0 GPH (High-Fire Input Capacities)

The 702CRD advanced oil burner features Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 1.7:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners.

Input
  High Fire: 6.0 to 13.2 GPH
    Low Fire: 3.5 to 7.5 GPH

 
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil

  Canada - No. 1 Oil or No. 2 Furnace Oil

 

Nozzle


(1) Required, pattern and angle vary with application



Fuel Unit

2-Stage, Dual Pressure 100/300 PSIG



Oil Valves

(2) Oil solenoid valve (safety and low fire valves)
    (1) Oil solenoid valve, pump mounted (high-fire valve)
     
Control
  Carlin 60200 Primary Control
     
Electrical
  Power: 120 vac/60Hz/1-Phase

  Limit Circuit Input (60200 Primary): 120 vac/60 Hz
    Control Circuit Load: 120 vac, 1.2 amps

  Motor: 1/2 HP, 3450 RPM, 60 Hz, Optional 115/208-230 vac, 60 Hz, 1 phase, 8.4/3.8-4.2 amps
    Motor Frame: 48-Frame, "N" Flange

  Oil Valve Power: 120 vac/60 Hz
    Damper Motor (With End Switch): Honeywell M436A

 
Ignition
 

Carlin Model 41000 solid state electronic ignition


  Ignition Voltage: 14,000 volts

 
Agencies
  UL Listed: US & Canada

 

Carlin 701 & 801 CRD Oil Burner

 

Commercial

Model 701 & 801 CRD Oil Burners

6.0 to 13.2 GPH & 11.4 to 19.8 GPH

The 701CRD and 801CRD advanced oil burners feature Carlin's adjustable combustion head assembly - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 2:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners.

Input
  701CRD: High Fire: 6.0 to 13.2 GPH, Low Fire: 3.6 to 6.6 GPH
    801CRD: High Fire: 11.4 to 19.8 GPH, Low Fire: 6.6 to 8.4 GPH

 
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil

  Canada - No. 1 Oil or No. 2 Furnace Oil

 

Nozzles


(1) Low Fire Nozzle, (1) High Fire Nozzle, pattern and angle vary with application



Fuel Unit

2-Stage, "B" Style, 150 PSIG



Oil Valves

(2) Oil solenoid valves
     
Control
  Carlin 60200 Primary Control
     
Electrical
  Power: 120 vac/60Hz/1-Phase

  Limit Circuit Input (60200 Primary): 120 vac/60 Hz
    Control Circuit Load: 120 vac, 1.2 amps

 

Motor:
701CRD: 1/2 HP, 3450 RPM, 115/208-230 vac, 60 Hz, 1 phase, 8.4/3.8-4.2 amps
801CRD: 3/4 HP, 3450 RPM, 60 Hz, 115/208-230 vac, 60 Hz, 1 phase, 9.8/4.8-4.9 amps. Optional 208-230/460 vac, 60 Hz, 3 phase, 3.0-3.2/1/6 amps

    Motor Frame:
701CRD:
48-Frame, "N" Flange
801CRD: 56C-Frame

  Oil Valve Power: 120 vac/60 Hz
    Damper Motor (With End Switch): Honeywell M436A

 
Ignition
 

Carlin Model 41000 solid state electronic ignition


  Ignition Voltage: 14,000 volts

 
Agencies
  UL Listed: US & Canada

 

Carlin 1050 & 1150 FFD Oil Burner

 

Commercial

Model 1050 & 1150 FFD Oil Burners

15.0 to 25.0 GPH & 20.0 to 35.0 GPH

The 1050FFD and 1150FFD advanced oil burners feature Carlin's flame-funnel combustion head design - for unmatched fuel/air mixing, smooth light-offs and quiet running. The automatically-closed air damper and low-high-low step modulation (approximately 2:1 turndown) improve efficiency by closer matching of output to demand and reduced stand-by losses - typically savings of 15-20% in seasonal fuel usage when compared to single-stage flame retention burners.

Input
  1050FFD: High Fire: 15.0 to 25.0 GPH, Low Fire: 9.0 to 12.0 GPH
    1150FFD: High Fire: 20.0 to 35.0 GPH, Low Fire: 12.0 to 15.0 GPH

 
Fuels
  U.S. - No. 1 or No. 2 Fuel Oil

  Canada - No. 1 Oil or No. 2 Furnace Oil

 

Nozzles


(3) 45° "SS" Hago



Fuel Unit

2-Stage, "H" Style, 100 PSIG



Oil Valves

(2) Oil solenoid valves
     
Control
  1050FFD (To 20 GPH Only): Carlin 60200 Primary Control
    1050FFD & 1150FFD (Over 20 GPH): Specify Control Set
     
Electrical
  Power: 120 vac/60Hz/1-Phase

  Limit Circuit Input (60200 Primary): 120 vac/60 Hz
    Control Circuit Load: 120 vac, 1.2 amps

 

Motor:
1050FFD: 1 HP, 3450 RPM, Standard 115/208-230 vac, 60 Hz, 1 Phase, 12.0/6.2 amps, Optional 208-230/460 vac, 60 Hz, 3 Phase, 3.7/1.85 amps
1150FFD: 1 1/2 HP, 3450 RPM, 60 Hz, Standard 115/208-230 vac, 60 Hz, 1 Phase, 13.4/7.4 amps, Optional 208-230/460 vac, 60 Hz, 3 Phase, 5.0/2.5 amps

    Motor Frame:
1050FFD:
56C Frame
1150FFD: 56C Frame

  Oil Valve Power: 120 vac/60 Hz
    Damper Motor (With End Switch): Honeywell M436A

 
Ignition
 

Carlin Model 41000 solid state electronic ignition


  Ignition Voltage: 14,000 volts

 
Agencies
  UL Listed: US & Canada